Respiratory endoscopy
search results for ""
Respiratory endoscopy
GuideSheathKits
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Biopsy Forceps | Area Compatibility | |
---|---|---|---|---|---|---|---|
N3041930 | K-202 | 1 |
![]() |
1050 mm | Oval, fenestrated |
![]() |
|
N3042130 | K-204 | 1 |
![]() |
1050 mm | Oval, fenestrated |
![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Biopsy Forceps |
Brush ø (A) |
Brush Length (B) |
Area Compatibility | |
---|---|---|---|---|---|---|---|---|---|
N3041830 | K-201 | 1 |
![]() |
1050 mm | Oval, fenestrated | 2.0 mm | 10 mm |
![]() |
|
N3042030 | K-203 | 1 |
![]() |
1050 mm | Oval, fenestrated | 2.0 mm | 10 mm |
![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Brush ø (A) |
Brush Length (B) |
Area Compatibility | |
---|---|---|---|---|---|---|---|---|
N5767430 | BC-205D-2010 | 10 |
![]() |
1150 mm | 2.0 mm | 10 mm |
![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Area Compatibility | |
---|---|---|---|---|---|---|
N5767330 | FB-433D | 4 |
![]() |
1150 mm |
![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Distal Tip ø |
Outer ø | Area Compatibility | |
---|---|---|---|---|---|---|---|---|
N3530530 | B5-2C | 1 |
![]() |
1050 mm | 5 Fr. | 11 mm |
![]() |
|
1066587 | B7-2C | 1 |
![]() |
1050 mm | 7 Fr. | 13 mm |
![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Opening Width ø |
Area Compatibility | |
---|---|---|---|---|---|---|---|
N6008530 | FG-214P | 1 |
![]() |
1900 mm | 3.8 mm |
![]() ![]() |
|
N6008730 | FG-232L | 1 |
![]() |
1621 mm | 7.3 mm |
![]() ![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Opening Width ø |
Area Compatibility | |
---|---|---|---|---|---|---|---|
N6009930 | FG-220P | 1 |
![]() |
1900 mm | 4.8 mm |
![]() ![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Opening Width ø |
Area Compatibility | |
---|---|---|---|---|---|---|---|
N6008430 | FG-804L | 1 |
![]() |
1650 mm | 14.0 mm |
![]() ![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Opening Width ø |
Basket Type | Area Compatibility | |
---|---|---|---|---|---|---|---|---|
N5402930 | FG-55D | 1 |
![]() |
1150 mm | 12 mm | 4 wires, parallel |
![]() |
|
N5402630 | FG-51D | 1 |
![]() |
1150 mm | 9 mm | 4 wires, helical |
![]() |
|
N5402730 | FG-52D | 1 |
![]() |
1150 mm | 8 mm | 3 wires, helical |
![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Opening Width ø |
Area Compatibility | |
---|---|---|---|---|---|---|---|
N5402830 | FG-54D | 1 |
![]() |
1150 mm | 10 mm |
![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Probe Tip Design |
For Use With |
Area Compatibility | |
---|---|---|---|---|---|---|---|---|
WA94002A | PA-211U | 10 |
![]() |
2200 mm | Axial | Olympus APU-300 |
![]() ![]() ![]() |
|
WA94003A | PA-212U | 10 |
![]() |
2200 mm | Axial | Olympus APU-300 |
![]() |
|
WA94004A | PA-210Z | 10 |
![]() |
3000 mm | Axial | Olympus APU-300 |
![]() |
|
WA94005A | PA-211Z | 10 |
![]() |
3000 mm | Axial | Olympus APU-300 | Enteroscopy | |
WA94006A | PA-221U | 10 |
![]() |
2200 mm | Lateral | Olympus APU-300 |
![]() ![]() ![]() |
|
WA94007A | PA-231U | 10 |
![]() |
2200 mm | Radial | Olympus APU-300 |
![]() ![]() ![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø | Outer ø |
For Use With |
Area Compatibility | |
---|---|---|---|---|---|---|---|
N3495330 | IBV-V5 | 1 |
![]() |
5 mm | IBV-C20, IBV-C26N |
![]() |
|
N3495430 | IBV-V6 | 1 |
![]() |
6 mm | IBV-C20, IBV-C26N |
![]() |
|
N3495530 | IBV-V7 | 1 |
![]() |
7 mm | IBV-C20, IBV-C26N |
![]() |
|
N5381200 | IBV-V9 | 1 |
![]() |
9 mm | IBV-C26N |
![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
For Use With |
Area Compatibility | |
---|---|---|---|---|---|---|---|
N3521830 | IBV-C20 | 1 |
![]() |
1141 mm | IBV-V5, IBV-V6, IBV-V7 |
![]() |
|
N5381300 | IBV-C26N | 1 |
![]() |
1020 mm | IBV-V5, IBV-V6, IBV-V7, IBV-V9 |
![]() |
Article number |
Article Name |
Quantity | Min. Working Channel ø |
Working Length |
Distal Tip ø |
Outer ø | Area Compatibility | |
---|---|---|---|---|---|---|---|---|
N5534500 | IBV-VSK | 1 |
![]() |
|||||
N3530530 | B5-2C | 1 |
![]() |
1050 mm | 5 Fr. | 11 mm |
![]() |
Article number |
Article Name |
Quantity | Description | Endoscope Compatibility | |
---|---|---|---|---|---|
K10020960 | MAJ-1632 | 50 | Single-use bite block | For all GI endoscopes and bronchoscopes |
Article number |
Article Name |
Quantity | Description | Endoscope Compatibility | Area Compatibility | |
---|---|---|---|---|---|---|
E0421114 | BB-O03-30-33-T | 100 | Single-use paediatric bite block | For all GI endoscopes and bronchoscopes |
![]() ![]() |
Article number |
Article Name |
Quantity | Description | Endoscope Compatibility | |
---|---|---|---|---|---|
1006886 | MA-651 | 1 | Broncho reusable bite block | For all bronchoscopes with a maximum insertion tube outer diameter of 7 mm or less |
Article number |
Article Name |
Quantity |
Working Length |
Description | Endoscope Compatibility | |
---|---|---|---|---|---|---|
N1002130 | MAJ-1058 | 5 | 60 mm | Flexible trocar system | Pleuroscopes: LTF-240, -260, -H290 |
Article number |
Article Name |
Quantity | Description | Endoscope Compatibility | |
---|---|---|---|---|---|
1078828 | MD-159 | 1 | Suction valve | Bronchoscopes: OES 20D | |
1078241 | MD-493 | 1 | Aspiration valve | Bronchoscopes: OES 20 Rhinolaryngoscopes: ENF-T3 Tracheal intubation scopes: LF-GP, -DP, -TP, -2, -T | |
NGL2166 | MAJ-209 | 20 | Single-use, sterile suction valve | Mobile airwayscopes: MAF-TM, MAF-GM, MAF-TM2, MAF-GM2, MAF-DM2 Bronchoscopes: OES 30, 40, 60, EVIS 190, 240, 260, 290, 1100, 1200 Ultrasonic bronchoscopes: BF-UC260-OL8, -UC260FW, -UC290F Pleuroscopes: LTF-240, -260, -H290 Rhinolaryngoscopes: ENF-VT, -VT2 |
Article number |
Article Name |
Quantity | Description | Endoscope Compatibility | |
---|---|---|---|---|---|
N1775730 | MAJ-1414 | 10 | Single-use, sterile biopsy valve | Ultrasonic bronchoscopes: BF-UC260-OL8, -UC260FW, -UC290F |
This site is intended for residents of European Countries, as well as Middle East and Africa only. Approved product indications, registrations, and presentations may differ between countries. For any other country, visit our company's global website at www.olympus-global.com or the company website for your country for information about the availability of our products where you live and to obtain the most current registration details and approved product label.