Luminal Patency

Biliary Stents

Single-use biliary covered stents with flaps (CCC)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers on the stent’s mesh and on every second anchoring flap (14 markers in total)
  • Reduced stent migration supported by four anchoring flaps on the distal end and a flared proximal end
  • Reduced tissue ingrowth achieved by silicone inner covering
  • For malignant and benign indications
  • Delivery device reloadable



Single-use biliary covered stents with flaps and two lassos (CCC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers on the stent’s mesh and on every second anchoring flap (14 markers in total)
  • Reduced stent migration supported by four anchoring flaps on the proximal end and a flared distal end
  • Short loop for repositioning and long proximal loop marked with a golden marker designed for inside-out removal
  • Reduced tissue ingrowth achieved by silicone inner covering
  • For malignant and benign indications
  • Delivery device reloadable



Single-use biliary covered stents with one lasso (CCC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Proximal lasso facilitates stent repositioning and removal
  • Reduced tissue ingrowth achieved by silicone inner covering
  • Reduced foreshortening compared to SHC
  • For malignant and benign indications
  • Stent can be recaptured



Single-use biliary covered stents (CCC) for percutaneous application

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Reduced tissue ingrowth achieved by silicone inner covering
  • For percutaneous application
  • Delivery device reloadable



Single-use biliary uncovered stents (NNN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Increased radial force and better conformity compared to SHS
  • Delivery device reloadable



Single-use Hilar Biliary Uncovered Stents for Percutaneous Application (NNN)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Delivery device reloadable



Single-use biliary uncovered stents (NNN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Stent can be recaptured



Single-use Biliary Uncovered Stents (NNN), TTS –
Distal Wire-guided, FAST™ Delivery System

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Stent can be recaptured



Single-use Hilar Biliary Uncovered Stents for Percutaneous Application (NNN)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Delivery device reloadable



Single-use biliary partially covered stents (NCN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 16 gold radiopaque markers
  • Reduced stent migration supported by uncovered flared ends
  • Delivery device reloadable



Single-use biliary partially covered stents (NC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends and uncovered proximal part
  • Delivery device reloadable



Single-use biliary covered stents (CCC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Proximal loop for effortless stent repositioning and removal
  • Increased drainage efficiency supported by hybrid design with multiple holes in the silicone membrane
  • Delivery device reloadable



Single-use biliary proximally covered stents with eight flaps, (NC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 16 gold radiopaque markers
  • Reduced stent migration supported by uncovered distal part and flaps
  • Delivery device reloadable



Single-use biliary stents proximally covered (NC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by uncovered distal part
  • Minimised leakage supported by silicone covering in the distal part
  • Delivery device reloadable



Single-use biliary stents proximally covered (NC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility under fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by uncovered distal end with flaps
  • Minimised leakage supported by silicone covering at the proximal part



Single-use drainage covered stents (CCC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Minimised leakage supported by large wheel design and full-length covering with silicone
  • Indicated for pancreatic drainage
  • Delivery device reloadable



HANAROSTENT Hot Plumber with Z-EUS IT

  • Intended for the drainage of a pancreatic pseudocyst or gallbladder through a transgastric or transduodenal approach
  • The luer lock enables the Z-EUS IT™ to be secured to the endoscope, assisting the user with stable procedure
  • Complete coverage of the Electrode Punch Tip (EPT) allows quick and smooth access to the target area
  • One-hand operation is now feasible with compact handle and easy manipulation
  • Easy stent removal with lasso



Single-use tracheobronchial covered stents (CCC)

  • Cross & Hook Nitinol wire structure for better flexibility and optimal wall adaption
  • Inner silicone membrane supports easy saliva flow and prevents ingrowth
  • Flared ends support anti-migration
  • 12 radiopaque markers allow enhanced fluoroscopic visibility
  • Fully covered with loops on both ends for easy removal
  • Ergonomic over-the-wire delivery system with soft olive tip for easy penetration of tight lesions



Single-use tracheobronchial covered stents (CCC)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Inner silicone membrane supports easy sputum flow and prevents ingrowth
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Fully covered stent and flare heads for antimigration
  • Proximal lasso for repositioning right after stent placement
  • Ergonomic over-the-wire delivery system with soft olive tip for easy penetration of soft lesions



Single-use tracheobronchial covered stents (CCC)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Inner silicone membrane supports easy sputum flow and prevents ingrowth
  • Excellent visibility during fluoroscopy due to 9 gold radiopaque markers
  • Fully covered stent and flare heads for antimigration
  • Proximal lasso for repositioning right after stent placement
  • Ergonomic over-the-wire delivery system with soft olive tip for easy penetration of soft lesions