Loading...
 

search results for ""

https://dam.olympus.com/transform/e7beb3c4-8afc-4d61-a38b-e528d2518066/surfer?io=transform:scale,width:2024,height:auto

Polypectomy, EMR and ESD

Endoscopic Mucosal Resection Kits

Single-use EMR Kit for lower GI

  • Ready-to-use kit for EMR in the lower GI tract
  • Set comprises spray catheter (PW-205V), injection needle (NM-400U-0425) and electrosurgical snare (SD-230U-20)



Single-use electrosurgical knives with knob-shaped tip and integrated jet function

  • Unique design for maximum performance
  • Handle with rotatable injection port allows injection into the submucosal space
  • Slim sheath with just the right degree of rigidity for stable dissection plus excellent suction
  • Easy two-step adjustment: Retracted and extended
  • 0.3 mm knob-shaped needle tip for smooth, reliable cutting; allows fibres to be hooked up
  • When the knife is retracted, the knob is only 0.1 mm high – for even safer marking and haemostasis
  • For a clear field of view, a distal attachment (D-201 series) may be used
  • To be used with OFP-2/OFP-3 flushing pumps and MAJ-1681/MAJ-1682 tubing



Single-use electrosurgical hook knives with integrated jet function

  • Unique design for maximum performance
  • Handle with rotatable injection port allows injection into the submucosal space
  • L-shaped, rotatable hook allows orientation of the tip parallel to the muscle layer of the GI wall; ensures optimal safety of the procedure even in complicated clinical situations, especially when fibrotic scar tissue is present in the operation field
  • For a clear field of view, a distal attachment (D-201 series) may be used
  • To be used with OFP-2/OFP-3 flushing pumps and MAJ-1681/MAJ-1682 tubing



Single-use electrosurgical triangle-tip knife with integrated jet function

  • Improved design with jet; ideal for POEM
  • Submucosal injection: Addition of new jet function enables saline injection after cutting – without switching devices
  • New smaller, thinner triangle tip
  • New round-shaped distal cover to support smooth manipulation even from tangential direction
  • No tip rotation needed; cutting can be performed in any direction
  • Can be used with Olympus OFP-2/OFP-3 flushing pumps and MAJ-1681/MAJ-1682 tubing



Single-use tubes for knives with jet function

  • Tubing to connect Olympus OFP-2/OFP-3 flushing pumps and MAJ-1681/MAJ-1682 tubing with Olympus ESD knives with jet function
  • Sterile, pre-assembled and ready to use
  • One-way check valve pre-attached to prevent backflow
  • Peristaltic tubing indicator-line markings for positioning in pump head for ease of use and optimal performance
  • Two different versions: with bottle cap or spike



Remote Control Cable for Flushing Pump




Single-use splinting tube

  • Splinting tube with inflatable balloon supporting the position of the endoscope within the colon
  • Suitable for complex therapeutic procedures such as EMR and ESD
  • Hypoallergenic, latex-free design
  • Smooth passage of the endoscope thanks to hydrophilic-coated silicone
  • Compatible with Balloon Control Unit OBCU



Single-Use Electrosurgical Insulated-Tip Knife – for Oesophagus

  • Triangle-shaped electrode for easier lateral incision and submucosal dissection
  • Insulated tip enables incision and dissection of large lesions in the stomach
  • Coil sheath with optimised rigidity to maintain maximum manoeuvrability
  • To ensure a clear field of view, a distal attachment (D-201 series) may be used



Single-use electrosurgical insulated-tip knives – for colon and oesophagus

  • Supports safer procedures in the oesophagus and colon
  • Specially designed, smaller insulated tip to improve manoeuvrability
  • Disk-shaped electrode enables smooth spark development
  • Coil sheath with optimised rigidity to maintain maximum manoeuvrability
  • To ensure a clear field of view, a distal attachment (D-201 series) may be used



Single-use electrosurgical hook knives

  • L-shaped hook for incision and dissection in longitudinal and lateral directions
  • To minimise invasion, the use of a distal attachment is recommended (D-201 series) to help maintain the field of view
  • Rotatable



Single-use electrosurgical triangle tip knife

  • Triangle-tipped knife for marking, incision and dissection
  • Conductive triangle tip for cutting the mucosa
  • No need to rotate the knife; cutting can be performed in any direction
  • Tip design suitable for controlling moderate bleeding
  • To ensure a clear field of view, a distal attachment (D-201 series) may be used



Single-use electrosurgical knife with knob-shaped tip

  • The 0.3 mm needle knife tip is knob-shaped for smooth and reliable cutting; additionally, it allows the hooking up of the submucosal fibres
  • Two different knife lengths are available for safe performance according to anatomical needs
  • Easy two-step adjustment: Retracted knife for marking and haemostasis; extended knife for incision and dissection
  • Slim sheath with just the right degree of rigidity for stable dissection, plus excellent suction
  • To ensure a clear field of view, a distal attachment (D-201 series) may be used



Single-use electrosurgical haemostatic forceps

  • To support endoscopic submucosal dissection with fast and reliable haemostasis
  • Anti-slip construction to securely grasp bleeding points
  • Simplified coagulation process during grasping
  • Rotating function
  • FD-410LR: Tapered tip for precise approach
  • FD-411QR/UR: Smaller distal cup to suit the colon’s thin wall



Single-use electrosurgical haemostatic forceps

  • For haemostasis in the stomach only
  • The forceps' shape has been optimised for securely grasping slippery, hard tissue and thick blood vessels
  • Maximum opening width is 6.5 mm



EndoClot® Submucosal Injection System

  • Designed to deliver a long-lasting mucosal lift with higher elevation and easy delivery
  • Intended for use in gastrointestinal endoscopic procedures for submucosal lift of polyps, adenomas, early stage cancers and other gastrointestinal mucosa lesions
  • Composed of Absorbable Modified Polymers (AMP®) particles derived from plant starch
  • Specially designed spiral syringe provides precise dosage of solution
  • To be mixed with saline solution



Single-use EndoClot® Syringe

  • Specially designed spiral syringe for injecting EndoClot ® SIS solution



Single-use grasping forceps to support gastric ESD

  • Single-use grasping forceps act like an extra hand to support gastric ESD
  • Opening width is 8 mm
  • Insertion portion length is 1950 mm
  • Two different diameters available



Single-use Endoscopic Lifting Device

FlexLifter_Logo_137218.tif
  • Over-the-scope endoscopic lifting device
  • Facilitates visualization of the submucosal and muscle layer during complex endoluminal procedures, by applying tissue traction
  • Locking function during tissue traction allows independent operation of other device in working channel
  • Designed to assist procedures in the colon and rectum



Single-use Needle Holder

SutuArt_Logo_137221.tif
  • Designed to to grasp and hold a suture needle or a suture in mucosal defect closure procedure within the stomach, colon and rectum
  • Special locking mechanism provides firm hold of the needle
  • Coil sheath facilitates 1:1 force transmition from the handle to the forceps
  • Exclusive design of the grasping forceps surface allows secure grasping of the needle
  • Ratchet function incorporated in the handle helps secure the locking mechanism, providing the firm grip of the needle