Loading...
 

search results for ""

https://dam.olympus.com/transform/dfd5e909-d7c1-41a8-959d-cc7e2d9ae85b/surfer?io=transform:scale,width:2024,height:auto

Luminal Patency

Biliary Stents

Single-use biliary uncovered stents (NNN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Stent can be recaptured



Single-use Biliary Uncovered Stents (NNN), TTS –
Distal Wire-guided, FAST™ Delivery System

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Stent can be recaptured



Single-use Hilar Biliary Uncovered Stents for Percutaneous Application (NNN)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Delivery device reloadable



Single-use biliary partially covered stents (NCN), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 16 gold radiopaque markers
  • Reduced stent migration supported by uncovered flared ends
  • Delivery device reloadable



Single-use biliary partially covered stents (NC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by flared ends and uncovered proximal part
  • Delivery device reloadable



Single-use biliary covered stents (CCC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by flared ends
  • Proximal loop for effortless stent repositioning and removal
  • Increased drainage efficiency supported by hybrid design with multiple holes in the silicone membrane
  • Delivery device reloadable



Single-use biliary proximally covered stents with eight flaps, (NC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to 16 gold radiopaque markers
  • Reduced stent migration supported by uncovered distal part and flaps
  • Delivery device reloadable



Single-use biliary stents proximally covered (NC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Reduced stent migration supported by uncovered distal part
  • Minimised leakage supported by silicone covering in the distal part
  • Delivery device reloadable



Single-use biliary stents proximally covered (NC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility under fluoroscopy due to 12 gold radiopaque markers
  • Reduced stent migration supported by uncovered distal end with flaps
  • Minimised leakage supported by silicone covering at the proximal part



Single-use drainage covered stents (CCC), TTS

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Excellent visibility during fluoroscopy due to nine gold radiopaque markers
  • Minimised leakage supported by large wheel design and full-length covering with silicone
  • Indicated for pancreatic drainage
  • Delivery device reloadable



HANAROSTENT Hot Plumber with Z-EUS IT

  • Intended for the drainage of a pancreatic pseudocyst or gallbladder through a transgastric or transduodenal approach
  • The luer lock enables the Z-EUS IT™ to be secured to the endoscope, assisting the user with stable procedure
  • Complete coverage of the Electrode Punch Tip (EPT) allows quick and smooth access to the target area
  • One-hand operation is now feasible with compact handle and easy manipulation
  • Easy stent removal with lasso



Single-use tracheobronchial covered stents (CCC)

  • Cross & Hook Nitinol wire structure for better flexibility and optimal wall adaption
  • Inner silicone membrane supports easy saliva flow and prevents ingrowth
  • Flared ends support anti-migration
  • 12 radiopaque markers allow enhanced fluoroscopic visibility
  • Fully covered with loops on both ends for easy removal
  • Ergonomic over-the-wire delivery system with soft olive tip for easy penetration of tight lesions



Single-use tracheobronchial covered stents (CCC)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Inner silicone membrane supports easy sputum flow and prevents ingrowth
  • Excellent visibility during fluoroscopy due to 12 gold radiopaque markers
  • Fully covered stent and flare heads for antimigration
  • Proximal lasso for repositioning right after stent placement
  • Ergonomic over-the-wire delivery system with soft olive tip for easy penetration of soft lesions



Single-use tracheobronchial covered stents (CCC)

  • Better flexibility and optimal wall adaption due to Cross & Hook Nitinol wire structure
  • Inner silicone membrane supports easy sputum flow and prevents ingrowth
  • Excellent visibility during fluoroscopy due to 9 gold radiopaque markers
  • Fully covered stent and flare heads for antimigration
  • Proximal lasso for repositioning right after stent placement
  • Ergonomic over-the-wire delivery system with soft olive tip for easy penetration of soft lesions



https://dam.olympus.com/transform/fa8cf36d-ba59-48e0-a36e-38ad481a3fe3/surfer?io=transform:scale,width:2024,height:auto

Biliary and pancreatic procedures

Guidewires

Single-use guidewire VisiGlide

  • Innovative 0.025" guidewire concept
  • 70 mm highly flexible tip for excellent passability
  • Optimal stiffness of the 0.025" diameter shaft for therapeutic instrument exchange
  • Special fluorine coatings for effortless manipulation
  • One-to-one torqueability
  • Exceptional endoscopic and fluoroscopic visibility
  • Innovative measurement functions



Single-use guidewire VisiGlide 2

  • Innovative 0.025" guidewire concept
  • 70 mm highly flexible tip, which is more tapered than VisiGlide to allow formation of α loop
  • Angled version has a shorter angled tip than VisiGlide to support insertion into tortuous anatomy and side branches
  • Optimal stiffness of the 0.025" diameter shaft for therapeutic instrument exchange
  • Special fluorine coatings for effortless manipulation
  • One-to-one torqueability
  • Exceptional endoscopic and fluoroscopic visibility
  • Innovative measurement functions



Single-use Guidewire Locking Device and Biopsy Cap

CleverLock_Logo_ET_catalog_91106.tif
  • Securely locks up to 3 guidewires (0.018” – 0.035”) independently in cases where multiple guidewires are used
  • Easy guidewire identification and convenient positioning for procedural efficiency
  • "Click to Lock" audible and tactile feedback instil confidence that the guidewire is securely locked
  • Integrated biopsy valve allows for smooth device exchange while preventing air/bile leakage
  • Intuitive, stable scope attachment of pre-assembled lock and biopsy valve, does not obstruct hands during device exchanges



Single-Use Distal Cover for Duodenoscopes

  • Allows better access for reprocessing accessories during manual cleaning
  • Disposable cap prevents unintended re-use
  • Transparent cap provides better visualization of the distal end



Distal-end Flushing Adapter for Duodenoscopes

  • Designed to direct flushing to the distal end of the duodenoscope during manual cleaning.



V-System single-use cannulae

  • Excellent visibility under fluoroscopy
  • Smooth distal profile
  • Integrated C-Hook and V-Marking